{"id":4492,"date":"2026-09-19T15:31:07","date_gmt":"2026-09-19T07:31:07","guid":{"rendered":"https:\/\/www.pansvalve.com\/?p=4492"},"modified":"2026-09-24T09:31:57","modified_gmt":"2026-09-24T01:31:57","slug":"how-to-size-a-valve-cv-calculation","status":"publish","type":"post","link":"https:\/\/www.pansvalve.com\/pt\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/","title":{"rendered":"How to Size a Valve: Cv, Kv &amp; Step-by-Step Calculation"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_88 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u00cdndice<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Alternar \u00cdndice\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Alternar<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.pansvalve.com\/pt\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/#Why_Does_Proper_Valve_Sizing_Matter\" >Why Does Proper Valve Sizing Matter?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.pansvalve.com\/pt\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/#What_Are_Cv_and_Kv\" >What Are Cv and Kv?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.pansvalve.com\/pt\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/#How_Do_You_Size_a_Valve_for_Liquid_Service\" >How Do You Size a Valve for Liquid Service?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.pansvalve.com\/pt\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/#What_Are_the_Basics_of_Gas_and_Steam_Sizing\" >What Are the Basics of Gas and Steam Sizing?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.pansvalve.com\/pt\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/#What_Are_the_Key_Sizing_Rules_of_Thumb\" >What Are the Key Sizing Rules of Thumb?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.pansvalve.com\/pt\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/#What_Are_the_Most_Common_Valve_Sizing_Mistakes\" >What Are the Most Common Valve Sizing Mistakes?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.pansvalve.com\/pt\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/#Step-by-Step_Worked_Example\" >Step-by-Step Worked Example<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.pansvalve.com\/pt\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/#What_Tools_and_Calculators_Are_Available_for_Valve_Sizing\" >What Tools and Calculators Are Available for Valve Sizing?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.pansvalve.com\/pt\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/#Frequently_Asked_Questions\" >Perguntas frequentes<\/a><\/li><\/ul><\/nav><\/div>\n\n<p class=\"wp-block-paragraph\">Valve sizing comes down to one number: Cv. Or Kv if you are working in metric. Selecting an appropriate Cv or Kv helps achieve the required capacity, but control performance across the operating range also depends on valve characteristics, rangeability, actuator and positioner performance, and the installed system. Get it wrong, and you end up with a valve that either chokes the system or sits nearly closed all day, destroying its own seat. PANS Valve manufactures <a href=\"https:\/\/www.pansvalve.com\/pt\/products\/floating-ball-valve\/\" data-type=\"link\" data-id=\"https:\/\/www.pansvalve.com\/products\/floating-ball-valve\/\" target=\"_blank\" rel=\"noreferrer noopener\">ball<\/a>, gate, <a href=\"https:\/\/www.pansvalve.com\/pt\/products\/forged-globe-valve\/\" data-type=\"link\" data-id=\"https:\/\/www.pansvalve.com\/products\/forged-globe-valve\/\" target=\"_blank\" rel=\"noreferrer noopener\">globo<\/a>, butterfly, and check valves across a full range of pressure classes and sizes, with technical support for valve selection and sizing across oil and gas, petrochemical, power-generation, and water-system applications.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Why_Does_Proper_Valve_Sizing_Matter\"><\/span>Why Does Proper Valve Sizing Matter?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"576\" data-src=\"https:\/\/www.pansvalve.com\/wp-content\/uploads\/2026\/09\/image1-6-1024x576.webp\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" alt=\"\" class=\"wp-image-4493 lazyload\"\/><noscript><img decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.pansvalve.com\/wp-content\/uploads\/2026\/09\/image1-6-1024x576.webp\" alt=\"\" class=\"wp-image-4493\" srcset=\"https:\/\/www.pansvalve.com\/wp-content\/uploads\/2026\/09\/image1-6-1024x576.webp 1024w, https:\/\/www.pansvalve.com\/wp-content\/uploads\/2026\/09\/image1-6-300x169.webp 300w, https:\/\/www.pansvalve.com\/wp-content\/uploads\/2026\/09\/image1-6-768x432.webp 768w, https:\/\/www.pansvalve.com\/wp-content\/uploads\/2026\/09\/image1-6-1536x864.webp 1536w, https:\/\/www.pansvalve.com\/wp-content\/uploads\/2026\/09\/image1-6-18x10.webp 18w, https:\/\/www.pansvalve.com\/wp-content\/uploads\/2026\/09\/image1-6.webp 1672w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/noscript><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Oversized. Undersized. Both are problems, just different ones.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">An oversized valve operates near closed at normal flow. Poor control. Seat wear. Instability at low openings. An undersized valve restricts the system, increases pressure drop, and prevents the plant from reaching required flow rates. Neither condition is acceptable in a process that depends on reliable flow control.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A properly sized control valve should operate within a stable and controllable travel range at minimum, normal, and maximum conditions, with adequate margin at both ends of travel. The preferred travel range depends on the valve design and project criteria. That is where stable, controllable operation lives. Outside that range, performance degrades fast.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_Are_Cv_and_Kv\"><\/span>What Are Cv and Kv?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Cv. Simple definition. The number of US gallons per minute of water at 60\u00b0F that flows through a valve with exactly 1 psi pressure drop across it. That is it. One number that tells you the flow capacity of any valve regardless of manufacturer.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Kv is the metric version. Cubic meters per hour of water at 1 bar pressure drop. Same concept, different units. Conversion between the two: Cv = 1.156 \u00d7 Kv. The valve Cv calculation formula for liquids is:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Cv = Q \u00d7 \u221a(SG \/ \u0394P)<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Q is flow rate in GPM. SG is specific gravity relative to water. \u0394P is pressure drop in psi. Straightforward. The complexity comes in how you define those inputs correctly.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_Do_You_Size_a_Valve_for_Liquid_Service\"><\/span>How Do You Size a Valve for Liquid Service?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">How to size a valve for liquids. Four steps. No shortcuts.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Step 1: Define operating conditions. Normal flow, minimum flow, maximum flow. Inlet and outlet pressures at each point. Calculate \u0394P for each condition. You need all three, not just the design point.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Step 2: Calculate required Cv. Calculate the required Cv at minimum, normal, and maximum operating conditions. Select the valve by comparing each required Cv with the manufacturer\u2019s Cv-versus-travel curve while preserving a suitable travel margin at maximum flow.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Step 3: Select the valve. Find a valve with published Cv at or above the calculated value. Confirm that normal flow occurs within the project\u2019s preferred control range and that sufficient additional travel remains for the maximum-flow condition. Not near closed. Not wide open.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Step 4: Check cavitation. Evaluate cavitation and liquid choked flow using absolute inlet pressure, vapor pressure, critical pressure, the valve pressure-recovery factor FL, and the applicable IEC\/ISA equations. Outlet pressure above vapor pressure alone does not rule out cavitation. Cavitation destroys trim, especially in globe valves with high pressure drop across the seat.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_Are_the_Basics_of_Gas_and_Steam_Sizing\"><\/span>What Are the Basics of Gas and Steam Sizing?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Different fluid. Different approach. The table below summarizes what changes across fluid types for valve sizing.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Fluid<\/strong><\/td><td><strong>Primary Concern<\/strong><\/td><td><strong>Key Variable<\/strong><\/td><td><strong>Main Risk<\/strong><\/td><\/tr><tr><td>Liquids<\/td><td>Constant density<\/td><td>Specific gravity, vapor pressure<\/td><td>Cavitation, flashing<\/td><\/tr><tr><td>Gases<\/td><td>Compressibility<\/td><td>Critical pressure ratio<\/td><td>Choked flow at sonic velocity<\/td><\/tr><tr><td>Vapor<\/td><td>Phase state<\/td><td>Superheat or saturation condition<\/td><td>Erosion, wet steam<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Gas sizing gets more complex because the fluid compresses. Choked flow kicks in when pressure drop hits around 50 percent of absolute inlet pressure. Once gas flow is choked at a given valve travel and upstream condition, further reduction of downstream pressure does not produce the normal increase in mass flow. Increasing valve travel can still increase effective Cv and flow capacity. Steam adds another layer. Saturated or superheated. The answer to that question changes the entire calculation approach.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_Are_the_Key_Sizing_Rules_of_Thumb\"><\/span>What Are the Key Sizing Rules of Thumb?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Four rules. Apply them every time.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Normal operating flow should land the valve at 60 to 80 percent open. Maximum flow should not push past 80 percent. Minimum controllable flow should not require less than 20 percent opening. Rangeability, the ratio of maximum to minimum controllable flow, must be confirmed against the valve\u2019s published specification. Violate any of these and the valve either loses control authority or wears out prematurely at one end of its travel.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_Are_the_Most_Common_Valve_Sizing_Mistakes\"><\/span>What Are the Most Common Valve Sizing Mistakes?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Five. All avoidable.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Oversizing. Too much Cv. Valve hunts near closed. Operating continuously near the seat may increase instability, velocity, and wear, potentially shortening trim and seat life.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Undersizing. Not enough Cv. System never reaches design flow. Pressure drop kills performance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ignoring cavitation. No cavitation check during sizing. Trim erodes. Noise. Vibration. Expensive repair.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mixing units. One input in metric, one in imperial. Calculation is off by a factor of two or more. Wrong valve gets ordered.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ignoring turndown. Sized only for maximum flow. Minimum flow condition makes the valve uncontrollable. Startup and low-load operation become problems.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Step-by-Step_Worked_Example\"><\/span>Step-by-Step Worked Example<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Water service. Here is the full calculation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Given: Flow rate 100 GPM. Specific gravity 1.0. Inlet pressure 50 psi. Outlet pressure 35 psi.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Step 1: \u0394P = 50 \u2013 35 = 15 psi.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Step 2: <em>Valve Cv calculation<\/em>. Cv = 100 \u00d7 \u221a(1.0 \/ 15) = 100 \u00d7 0.258 = 25.8. Select a valve with Cv of at least 26.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Step 3: Confirm the selected valve delivers 100 GPM at 60 to 80 percent open under normal operating conditions. If it only reaches 100 GPM near fully open, the valve is undersized for good control.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Step 4: Cavitation check. Outlet pressure is 35 psi. Verify this stays above the vapor pressure of water at operating temperature. At 60\u00b0F, the vapor pressure of water is approximately 0.26 psi. 35 psi is well above that. No cavitation risk in this example.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_Tools_and_Calculators_Are_Available_for_Valve_Sizing\"><\/span>What Tools and Calculators Are Available for Valve Sizing?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Several valve sizing calculator tools exist. Online Cv calculators from major valve manufacturers accept flow rate, pressure drop, specific gravity, and temperature, then return required Cv with cavitation and choked flow warnings. ISA formal sizing equations cover liquid, gas, and steam in detail. Specialized sizing software calculates Reynolds number, cavitation index, and critical pressure ratio automatically and flags problems in the output. Most serious sizing programs will also recommend alternate sizing routines when laminar flow conditions are detected.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For PANS Valve product selection and sizing support, <a href=\"https:\/\/www.pansvalve.com\/pt\/contact-us\/\">contact PANS Va<\/a><a href=\"https:\/\/www.pansvalve.com\/pt\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\">l<\/a><a href=\"https:\/\/www.pansvalve.com\/pt\/contact-us\/\">ve<\/a> for technical assistance and project-specific valve sizing guidance across ball, <a href=\"https:\/\/www.pansvalve.com\/pt\/products\/wedge-gate-valve\/\" data-type=\"link\" data-id=\"https:\/\/www.pansvalve.com\/products\/wedge-gate-valve\/\" target=\"_blank\" rel=\"noreferrer noopener\">port\u00e3o<\/a>, globe, butterfly, and <a href=\"https:\/\/www.pansvalve.com\/pt\/products\/cast-swing-check-valve\/\" data-type=\"link\" data-id=\"https:\/\/www.pansvalve.com\/products\/cast-swing-check-valve\/\" target=\"_blank\" rel=\"noreferrer noopener\">v\u00e1lvula de reten\u00e7\u00e3o<\/a> applications.<\/p>\n\n\n\n<style>\n  \/* \u5bb9\u5668\u57fa\u672c\u6837\u5f0f *\/\n  .nav-card-container {\n    position: relative;\n    width: 100%; \/* \u4fee\u6539\u4e3a 100% \u5bbd\u5ea6 *\/\n    height: 280px;\n    border-radius: 8px;\n    overflow: hidden;\n    display: flex;\n    flex-direction: column;\n    justify-content: center;\n    align-items: center; \/* \u786e\u4fdd\u5185\u5bb9\u5728\u4ea4\u53c9\u8f74\u4e0a\u5c45\u4e2d *\/\n    text-align: center; \/* \u786e\u4fdd\u6587\u672c\u5c45\u4e2d\u5bf9\u9f50 *\/\n    font-family: 'Arial', sans-serif;\n    \/* \u8fd8\u539f\u4e3a\u539f\u6765\u7684\u80cc\u666f\u56fe\u7247 *\/\n    background-image: url('https:\/\/www.pansvalve.com\/wp-content\/uploads\/2022\/03\/%E7%BB%84-2699.jpg');\n    background-size: cover;\n    background-position: center;\n    box-shadow: 0 4px 15px rgba(0,0,0,0.2);\n  }\n\n  \/* 0.3 \u900f\u660e\u5ea6\u9ed1\u8272\u906e\u7f69\uff1a\u786e\u4fdd\u767d\u8272\u6587\u5b57\u6e05\u6670\u53ef\u89c1 *\/\n  .nav-card-container::before {\n    content: \"\";\n    position: absolute;\n    top: 0;\n    left: 0;\n    width: 100%;\n    height: 100%;\n    background-color: rgba(0, 0, 0, 0.3); \/* \u8fd8\u539f\u4e3a 0.3 \u7684\u900f\u660e\u5ea6 *\/\n    z-index: 1;\n  }\n\n  \/* \u5185\u5bb9\u5c42\uff1a\u7f6e\u4e8e\u906e\u7f69\u4e0a\u65b9 *\/\n  .nav-content {\n    position: relative;\n    z-index: 2;\n    padding: 20px;\n    \/* \u5982\u679c\u9700\u8981\u66f4\u4e25\u683c\u7684\u5c45\u4e2d\u63a7\u5236\uff0c\u53ef\u4ee5\u5728\u8fd9\u91cc\u4e5f\u52a0\u4e0a text-align: center; *\/\n  }\n\n  \/* \u6807\u9898\u6587\u5b57\u6837\u5f0f *\/\n  .nav-description {\n    color: #ffffff;\n    font-size: 1.25rem;\n    font-weight: 600;\n    line-height: 1.5;\n    margin-bottom: 20px;\n    text-shadow: 1px 1px 5px rgba(0,0,0,0.6);\n  }\n\n  \/* --- \u4f18\u5316\u540e\u7684\u6309\u94ae\u6837\u5f0f --- *\/\n  .nav-button {\n    display: inline-block;\n    padding: 10px 28px;\n    background-color: #D70C19; \/* \u54c1\u724c\u7ea2\u80cc\u666f *\/\n    color: #ffffff !important;  \/* \u5f3a\u5236\u6b63\u5e38\u72b6\u6001\u4e0b\u6587\u5b57\u4e3a\u767d\u8272 *\/\n    text-decoration: none;\n    font-size: 14px;\n    font-weight: bold;\n    border: 2px solid #D70C19;\n    border-radius: 4px;\n    transition: all 0.3s ease;\n    cursor: pointer;\n    letter-spacing: 0.5px;\n  }\n\n  \/* \u60ac\u505c\u72b6\u6001\uff1a\u767d\u5e95\u7ea2\u5b57\uff0c\u589e\u5f3a\u89c6\u89c9\u53cd\u9988 *\/\n  .nav-button:hover {\n    background-color: #ffffff;\n    color: #D70C19 !important; \/* \u60ac\u505c\u65f6\u6587\u5b57\u53d8\u4e3a\u7ea2\u8272 *\/\n    border-color: #ffffff;\n    box-shadow: 0 4px 10px rgba(0,0,0,0.3);\n  }\n<\/style>\n\n<!-- \u4e3a\u5bb9\u5668\u6dfb\u52a0\u4e86 role \u548c aria-label \u5c5e\u6027\uff0c\u4ee5\u6ee1\u8db3\u80cc\u666f\u56fe\u7247\u7684 SEO \u548c\u65e0\u969c\u788d\u8bc6\u522b\u9700\u6c42 -->\n<div class=\"nav-card-container\" role=\"img\" aria-label=\"Base de fabrica\u00e7\u00e3o de v\u00e1lvulas e oficina da PANS com 60.000 metros quadrados\">\n  <div class=\"nav-content\">\n    <p class=\"nav-description\">Explore PANS Comprehensive Range of High-Performance Industrial Valves<\/p>\n    <a href=\"https:\/\/www.pansvalve.com\/pt\/product\/\" class=\"nav-button\">SABER MAIS<\/a>\n  <\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Frequently_Asked_Questions\"><\/span>Perguntas frequentes<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">What are standard valve sizes?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Available nominal sizes and pressure classes depend on the valve type, applicable product and end-connection standards, material, and manufacturer\u2019s qualified design range. Confirm the permitted size\u2013class combination for the specific valve. The correct size for a specific application is determined by Cv calculation, not pipe diameter alone.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What are the rules of thumb for valve sizing?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Normal flow should produce 60 to 80 percent valve opening. Maximum flow should not exceed 80 percent open. Minimum flow should not require less than 20 percent opening. These ranges ensure stable control authority across the full operating range of the system.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">How do you size a pressure relief valve?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pressure relief valve sizing follows different methods from control valve sizing. It is based on required relieving capacity at set pressure, fluid type, and allowable overpressure. API 520 and API 521 govern pressure relief valve sizing for oil and gas and petrochemical applications.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What is the difference between Cv and Kv?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Cv is the imperial flow coefficient measuring US gallons per minute of water at 1 psi pressure drop. Kv is the metric equivalent measuring cubic meters per hour at 1 bar pressure drop. The conversion factor is Cv = 1.156 \u00d7 Kv.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-white-color has-red-background-color has-text-color has-background has-link-color wp-element-button\" href=\"https:\/\/www.pansvalve.com\/pt\/contact-us\/\">Obtenha uma cota\u00e7\u00e3o<\/a><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Valve sizing comes down to one number: Cv. Or Kv if you are working in metric. Selecting an appropriate Cv or Kv helps achieve the required capacity, but control performance across the operating range also depends on valve characteristics, rangeability, actuator and positioner performance, and the installed system. Get it wrong, and you end up [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4494,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[203],"tags":[],"class_list":["post-4492","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industrial-valves"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Valve Sizing and Cv Calculation: Liquid, Gas, and Steam Flow Capacity Guide<\/title>\n<meta name=\"description\" content=\"Valve sizing determines flow capacity using Cv or Kv. Four-step liquid sizing, gas choked flow, and steam phase calculation. Proper Cv selection prevents cavitation, oversizing, and seat damage in control valves for process systems.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.pansvalve.com\/pt\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/\" \/>\n<meta property=\"og:locale\" content=\"pt_PT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Valve Sizing and Cv Calculation: Liquid, Gas, and Steam Flow Capacity Guide\" \/>\n<meta property=\"og:description\" content=\"Valve sizing determines flow capacity using Cv or Kv. Four-step liquid sizing, gas choked flow, and steam phase calculation. Proper Cv selection prevents cavitation, oversizing, and seat damage in control valves for process systems.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.pansvalve.com\/pt\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/\" \/>\n<meta property=\"og:site_name\" content=\"Industrial Valve Manufacturer and Company from China\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-19T07:31:07+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-24T01:31:57+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.pansvalve.com\/wp-content\/uploads\/2026\/09\/image2-5.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1672\" \/>\n\t<meta property=\"og:image:height\" content=\"941\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tempo estimado de leitura\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/blog\\\/industrial-valves\\\/how-to-size-a-valve-cv-calculation\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/blog\\\/industrial-valves\\\/how-to-size-a-valve-cv-calculation\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/#\\\/schema\\\/person\\\/246e471ae246e0f35793a4f0b10b61bf\"},\"headline\":\"How to Size a Valve: Cv, Kv &amp; Step-by-Step Calculation\",\"datePublished\":\"2026-09-19T07:31:07+00:00\",\"dateModified\":\"2026-09-24T01:31:57+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/blog\\\/industrial-valves\\\/how-to-size-a-valve-cv-calculation\\\/\"},\"wordCount\":1296,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/blog\\\/industrial-valves\\\/how-to-size-a-valve-cv-calculation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.pansvalve.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/image2-5.webp\",\"articleSection\":[\"industrial valves\"],\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.pansvalve.com\\\/blog\\\/industrial-valves\\\/how-to-size-a-valve-cv-calculation\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/blog\\\/industrial-valves\\\/how-to-size-a-valve-cv-calculation\\\/\",\"url\":\"https:\\\/\\\/www.pansvalve.com\\\/blog\\\/industrial-valves\\\/how-to-size-a-valve-cv-calculation\\\/\",\"name\":\"Valve Sizing and Cv Calculation: Liquid, Gas, and Steam Flow Capacity Guide\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/blog\\\/industrial-valves\\\/how-to-size-a-valve-cv-calculation\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/blog\\\/industrial-valves\\\/how-to-size-a-valve-cv-calculation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.pansvalve.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/image2-5.webp\",\"datePublished\":\"2026-09-19T07:31:07+00:00\",\"dateModified\":\"2026-09-24T01:31:57+00:00\",\"description\":\"Valve sizing determines flow capacity using Cv or Kv. Four-step liquid sizing, gas choked flow, and steam phase calculation. Proper Cv selection prevents cavitation, oversizing, and seat damage in control valves for process systems.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/blog\\\/industrial-valves\\\/how-to-size-a-valve-cv-calculation\\\/#breadcrumb\"},\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.pansvalve.com\\\/blog\\\/industrial-valves\\\/how-to-size-a-valve-cv-calculation\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/blog\\\/industrial-valves\\\/how-to-size-a-valve-cv-calculation\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.pansvalve.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/image2-5.webp\",\"contentUrl\":\"https:\\\/\\\/www.pansvalve.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/image2-5.webp\",\"width\":1672,\"height\":941,\"caption\":\"Industrial valve next to Cv sizing calculation sheet in plant\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/blog\\\/industrial-valves\\\/how-to-size-a-valve-cv-calculation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.pansvalve.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Size a Valve: Cv, Kv &amp; Step-by-Step Calculation\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/#website\",\"url\":\"https:\\\/\\\/www.pansvalve.com\\\/\",\"name\":\"Leading Plug Vavle, Ball Valve, Gate Valve Manufacturer of China\",\"description\":\"Involving six ranges and thousands of varieties, for control valve, cyogenic valve, gate valve, globe valve, ball valve, butterfly valve, power station valve, oxygen valve, hydraulic control valve, thread valve and Antibiotic valve.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/#organization\"},\"alternateName\":\"PANS Valve\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.pansvalve.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-PT\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/#organization\",\"name\":\"PANS Valve\",\"alternateName\":\"PANS\",\"url\":\"https:\\\/\\\/www.pansvalve.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.pansvalve.com\\\/wp-content\\\/uploads\\\/2022\\\/04\\\/\u6d59\u4e1c2.png\",\"contentUrl\":\"https:\\\/\\\/www.pansvalve.com\\\/wp-content\\\/uploads\\\/2022\\\/04\\\/\u6d59\u4e1c2.png\",\"width\":148,\"height\":52,\"caption\":\"PANS Valve\"},\"image\":{\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/#\\\/schema\\\/person\\\/246e471ae246e0f35793a4f0b10b61bf\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a5897a878f3bac4cb5dceceea12ed045a5e21138d217ad59263f373f4e992038?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a5897a878f3bac4cb5dceceea12ed045a5e21138d217ad59263f373f4e992038?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a5897a878f3bac4cb5dceceea12ed045a5e21138d217ad59263f373f4e992038?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"https:\\\/\\\/www.pansvalve.com\"],\"url\":\"https:\\\/\\\/www.pansvalve.com\\\/pt\\\/author\\\/admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Valve Sizing and Cv Calculation: Liquid, Gas, and Steam Flow Capacity Guide","description":"Valve sizing determines flow capacity using Cv or Kv. Four-step liquid sizing, gas choked flow, and steam phase calculation. Proper Cv selection prevents cavitation, oversizing, and seat damage in control valves for process systems.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.pansvalve.com\/pt\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/","og_locale":"pt_PT","og_type":"article","og_title":"Valve Sizing and Cv Calculation: Liquid, Gas, and Steam Flow Capacity Guide","og_description":"Valve sizing determines flow capacity using Cv or Kv. Four-step liquid sizing, gas choked flow, and steam phase calculation. Proper Cv selection prevents cavitation, oversizing, and seat damage in control valves for process systems.","og_url":"https:\/\/www.pansvalve.com\/pt\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/","og_site_name":"Industrial Valve Manufacturer and Company from China","article_published_time":"2026-09-19T07:31:07+00:00","article_modified_time":"2026-09-24T01:31:57+00:00","og_image":[{"width":1672,"height":941,"url":"https:\/\/www.pansvalve.com\/wp-content\/uploads\/2026\/09\/image2-5.webp","type":"image\/webp"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"admin","Tempo estimado de leitura":"7 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.pansvalve.com\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/#article","isPartOf":{"@id":"https:\/\/www.pansvalve.com\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/"},"author":{"name":"admin","@id":"https:\/\/www.pansvalve.com\/#\/schema\/person\/246e471ae246e0f35793a4f0b10b61bf"},"headline":"How to Size a Valve: Cv, Kv &amp; Step-by-Step Calculation","datePublished":"2026-09-19T07:31:07+00:00","dateModified":"2026-09-24T01:31:57+00:00","mainEntityOfPage":{"@id":"https:\/\/www.pansvalve.com\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/"},"wordCount":1296,"commentCount":0,"publisher":{"@id":"https:\/\/www.pansvalve.com\/#organization"},"image":{"@id":"https:\/\/www.pansvalve.com\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/#primaryimage"},"thumbnailUrl":"https:\/\/www.pansvalve.com\/wp-content\/uploads\/2026\/09\/image2-5.webp","articleSection":["industrial valves"],"inLanguage":"pt-PT","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.pansvalve.com\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.pansvalve.com\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/","url":"https:\/\/www.pansvalve.com\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/","name":"Valve Sizing and Cv Calculation: Liquid, Gas, and Steam Flow Capacity Guide","isPartOf":{"@id":"https:\/\/www.pansvalve.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.pansvalve.com\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/#primaryimage"},"image":{"@id":"https:\/\/www.pansvalve.com\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/#primaryimage"},"thumbnailUrl":"https:\/\/www.pansvalve.com\/wp-content\/uploads\/2026\/09\/image2-5.webp","datePublished":"2026-09-19T07:31:07+00:00","dateModified":"2026-09-24T01:31:57+00:00","description":"Valve sizing determines flow capacity using Cv or Kv. Four-step liquid sizing, gas choked flow, and steam phase calculation. Proper Cv selection prevents cavitation, oversizing, and seat damage in control valves for process systems.","breadcrumb":{"@id":"https:\/\/www.pansvalve.com\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/#breadcrumb"},"inLanguage":"pt-PT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.pansvalve.com\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/"]}]},{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/www.pansvalve.com\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/#primaryimage","url":"https:\/\/www.pansvalve.com\/wp-content\/uploads\/2026\/09\/image2-5.webp","contentUrl":"https:\/\/www.pansvalve.com\/wp-content\/uploads\/2026\/09\/image2-5.webp","width":1672,"height":941,"caption":"Industrial valve next to Cv sizing calculation sheet in plant"},{"@type":"BreadcrumbList","@id":"https:\/\/www.pansvalve.com\/blog\/industrial-valves\/how-to-size-a-valve-cv-calculation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.pansvalve.com\/"},{"@type":"ListItem","position":2,"name":"How to Size a Valve: Cv, Kv &amp; Step-by-Step Calculation"}]},{"@type":"WebSite","@id":"https:\/\/www.pansvalve.com\/#website","url":"https:\/\/www.pansvalve.com\/","name":"Fabricante l\u00edder de v\u00e1lvulas de encaixe, v\u00e1lvulas de esfera e v\u00e1lvulas de gaveta da China","description":"Envolvendo seis faixas e milhares de variedades, para v\u00e1lvula de controle, v\u00e1lvula ciog\u00eanica, v\u00e1lvula gaveta, v\u00e1lvula globo, v\u00e1lvula esf\u00e9rica, v\u00e1lvula borboleta, v\u00e1lvula de central el\u00e9trica, v\u00e1lvula de oxig\u00eanio, v\u00e1lvula de controle hidr\u00e1ulico, v\u00e1lvula de rosca e v\u00e1lvula antibi\u00f3tica.","publisher":{"@id":"https:\/\/www.pansvalve.com\/#organization"},"alternateName":"PANS Valve","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.pansvalve.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-PT"},{"@type":"Organization","@id":"https:\/\/www.pansvalve.com\/#organization","name":"V\u00e1lvula PANS","alternateName":"PANS","url":"https:\/\/www.pansvalve.com\/","logo":{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/www.pansvalve.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.pansvalve.com\/wp-content\/uploads\/2022\/04\/\u6d59\u4e1c2.png","contentUrl":"https:\/\/www.pansvalve.com\/wp-content\/uploads\/2022\/04\/\u6d59\u4e1c2.png","width":148,"height":52,"caption":"PANS Valve"},"image":{"@id":"https:\/\/www.pansvalve.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.pansvalve.com\/#\/schema\/person\/246e471ae246e0f35793a4f0b10b61bf","name":"administrador","image":{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/secure.gravatar.com\/avatar\/a5897a878f3bac4cb5dceceea12ed045a5e21138d217ad59263f373f4e992038?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/a5897a878f3bac4cb5dceceea12ed045a5e21138d217ad59263f373f4e992038?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/a5897a878f3bac4cb5dceceea12ed045a5e21138d217ad59263f373f4e992038?s=96&d=mm&r=g","caption":"admin"},"sameAs":["https:\/\/www.pansvalve.com"],"url":"https:\/\/www.pansvalve.com\/pt\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.pansvalve.com\/pt\/wp-json\/wp\/v2\/posts\/4492","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pansvalve.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pansvalve.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pansvalve.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pansvalve.com\/pt\/wp-json\/wp\/v2\/comments?post=4492"}],"version-history":[{"count":3,"href":"https:\/\/www.pansvalve.com\/pt\/wp-json\/wp\/v2\/posts\/4492\/revisions"}],"predecessor-version":[{"id":4514,"href":"https:\/\/www.pansvalve.com\/pt\/wp-json\/wp\/v2\/posts\/4492\/revisions\/4514"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.pansvalve.com\/pt\/wp-json\/wp\/v2\/media\/4494"}],"wp:attachment":[{"href":"https:\/\/www.pansvalve.com\/pt\/wp-json\/wp\/v2\/media?parent=4492"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pansvalve.com\/pt\/wp-json\/wp\/v2\/categories?post=4492"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pansvalve.com\/pt\/wp-json\/wp\/v2\/tags?post=4492"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}