{"id":2304,"date":"2026-11-17T09:00:00","date_gmt":"2026-11-17T01:00:00","guid":{"rendered":"https:\/\/www.pansvalve.com\/?p=2304"},"modified":"2026-11-24T14:09:16","modified_gmt":"2026-11-24T06:09:16","slug":"globe-valve-vs-plug-valve","status":"publish","type":"post","link":"https:\/\/www.pansvalve.com\/ar\/blog\/globe-valve\/globe-valve-vs-plug-valve\/","title":{"rendered":"\u0635\u0645\u0627\u0645 \u0627\u0644\u0643\u0631\u0629 \u0645\u0642\u0627\u0628\u0644 \u0635\u0645\u0627\u0645 \u0627\u0644\u0642\u0627\u0628\u0633: \u0623\u064a\u0647\u0645\u0627 \u0645\u0646\u0627\u0633\u0628 \u0644\u0646\u0638\u0627\u0645\u0643\u061f"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_91 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.pansvalve.com\/ar\/blog\/globe-valve\/globe-valve-vs-plug-valve\/#Quick_answer\" >Quick answer:<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.pansvalve.com\/ar\/blog\/globe-valve\/globe-valve-vs-plug-valve\/#What_is_a_Globe_Valve\" >What is a Globe Valve?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.pansvalve.com\/ar\/blog\/globe-valve\/globe-valve-vs-plug-valve\/#What_is_a_Plug_Valve\" >What is a Plug Valve?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.pansvalve.com\/ar\/blog\/globe-valve\/globe-valve-vs-plug-valve\/#Globe_valve_vs_plug_valve_compare_the_same_duty\" >Globe valve vs plug valve: compare the same duty<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.pansvalve.com\/ar\/blog\/globe-valve\/globe-valve-vs-plug-valve\/#Which_design_fits_the_operating_conditions\" >Which design fits the operating conditions?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.pansvalve.com\/ar\/blog\/globe-valve\/globe-valve-vs-plug-valve\/#Conclusion\" >Conclusion<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.pansvalve.com\/ar\/blog\/globe-valve\/globe-valve-vs-plug-valve\/#FAQs_for_industrial_buyers\" >FAQs for industrial buyers<\/a><\/li><\/ul><\/nav><\/div>\n\n<style>\n.pans-globe-plug-article{--flow-red:#e60012;max-width:1100px;margin:0 auto;background:#fff;color:#333;font:17px\/1.8 Arial,Helvetica,sans-serif;overflow-wrap:break-word}\n.pans-globe-plug-article *{box-sizing:border-box}\n.pans-globe-plug-article .flow-chapter{display:flow-root;margin:0 0 30px}\n.pans-globe-plug-article h2{clear:both;margin:32px 0 22px;padding-left:16px;border-left:5px solid #e60012;color:#333;font-size:clamp(24px,3vw,30px);line-height:1.4;font-weight:700}\n.pans-globe-plug-article .flow-chapter:first-child{padding:24px 28px;background:#f5f5f5;border-top:4px solid #e60012;border-radius:0 0 8px 8px}\n.pans-globe-plug-article .flow-chapter:first-child h2{margin-top:0;border:0;padding:0;color:#e60012}\n.pans-globe-plug-article h3{clear:both;margin:28px 0 16px;font-size:22px;line-height:1.45;color:#333}\n.pans-globe-plug-article p{margin:0 0 17px}.pans-globe-plug-article ul,.pans-globe-plug-article ol{margin:0 0 20px;padding:18px 22px 18px 42px;background:#f5f5f5;border-radius:6px;list-style:disc;overflow:hidden}.pans-globe-plug-article li{margin:5px 0}.pans-globe-plug-article li::marker{color:#e60012}\n.pans-globe-plug-article a{color:#d70011;text-decoration:underline;text-underline-offset:4px}.pans-globe-plug-article a:hover{color:#333}.pans-globe-plug-article a:focus-visible,.pans-globe-plug-article [tabindex]:focus-visible{outline:3px solid #e60012;outline-offset:4px}\n.pans-globe-plug-article img{max-width:100%;height:auto}.pans-globe-plug-article figure{margin:0 0 20px}.pans-globe-plug-article .alignright{float:right;margin:0 0 20px 24px;width:200px;max-width:40%}.pans-globe-plug-article .alignright img{display:block;width:100%;height:auto}\n.pans-globe-plug-article .flow-design-checks{clear:both;background:#fafafa;border:1px solid #dedede;border-top:3px solid #e60012;border-radius:8px;padding:24px;margin:30px 0 0}.pans-globe-plug-article .flow-design-checks h3{margin:0 0 18px}.pans-globe-plug-article .flow-design-checks p:last-child{margin:20px 0 0}\n.pans-globe-plug-article .flow-table-scroll{width:100%;overflow-x:auto}.pans-globe-plug-article table{border-collapse:collapse;width:100%;min-width:650px;font-size:15px;line-height:1.7;text-align:left;margin:0}.pans-globe-plug-article th,.pans-globe-plug-article td{padding:16px;border:1px solid #ddd;vertical-align:top;white-space:normal}.pans-globe-plug-article thead th{background:#333;color:#fff;border-color:#555;font-weight:700}.pans-globe-plug-article tbody th{color:#d70011;background:#fff;width:17%;font-weight:600}.pans-globe-plug-article tbody td{background:#fff}.pans-globe-plug-article tbody tr:nth-child(even) td,.pans-globe-plug-article tbody tr:nth-child(even) th{background:#f3f3f3}\n.pans-globe-plug-article .cldg-card-container{display:flex;flex-wrap:wrap;width:100%;margin:25px 0;border:1px solid #e0e0e0;border-radius:8px;overflow:hidden;background:#fff}.pans-globe-plug-article .cldg-card-text-column{flex:0 0 55%;padding:30px;display:flex;flex-direction:column;justify-content:center;align-items:flex-start}.pans-globe-plug-article .cldg-card-image-column{flex:0 0 45%;display:flex;align-items:center;padding:16px;background:#f8f8f8;min-height:250px}.pans-globe-plug-article .cldg-card-image-column img{width:100%;height:auto;object-fit:contain;display:block}.pans-globe-plug-article .cldg-card-title{font-size:24px;font-weight:600;color:#111;line-height:1.3;margin:0 0 15px}.pans-globe-plug-article .cldg-card-description{font-size:16px;color:#444;line-height:1.6;margin-bottom:20px}.pans-globe-plug-article a.cldg-card-cta-button{display:inline-block;padding:10px 26px;font-size:16px;font-weight:600;color:#d70c19;background:#fff;border:2px solid #d70c19;border-radius:5px;text-decoration:none;text-align:center}.pans-globe-plug-article a.cldg-card-cta-button:hover{background:#d70c19;color:#fff}\n.pans-globe-plug-article .wp-block-buttons{display:flex;justify-content:center;flex-wrap:wrap;margin:26px 0;gap:12px}.pans-globe-plug-article a.wp-block-button__link{display:inline-block;padding:13px 32px;border-radius:5px;background:#e60012;border:2px solid #e60012;color:#fff;font-size:17px;line-height:1.5;font-weight:600;text-align:center;text-decoration:none;cursor:pointer}.pans-globe-plug-article a.wp-block-button__link:hover{background:#333;border-color:#333;color:#fff}\n@media(max-width:768px){.pans-globe-plug-article .cldg-card-container{flex-direction:column}.pans-globe-plug-article .cldg-card-text-column,.pans-globe-plug-article .cldg-card-image-column{flex:0 0 auto;width:100%}.pans-globe-plug-article .cldg-card-text-column{padding:24px}.pans-globe-plug-article .cldg-card-image-column{min-height:0}.pans-globe-plug-article .cldg-card-image-column img{max-height:320px}}\n@media(max-width:480px){.pans-globe-plug-article{font-size:16px}.pans-globe-plug-article .flow-chapter:first-child{padding:20px 18px}.pans-globe-plug-article .flow-design-checks{padding:18px 14px}.pans-globe-plug-article h3{font-size:21px}.pans-globe-plug-article .alignright{float:none;margin:0 auto 20px;max-width:100%;width:240px}.pans-globe-plug-article ul,.pans-globe-plug-article ol{padding-left:32px}}\n\n.pans-globe-plug-article .flow-table-scroll{margin:24px 0 32px;border:1px solid #ddd;border-radius:8px;max-width:100%}\n.pans-globe-plug-article table{min-width:800px}.pans-globe-plug-article tbody th{width:18%}\n.pans-globe-plug-article .product-card{display:flex;align-items:center;border:1px solid #ddd;border-top:3px solid #e60012;border-radius:10px;overflow:hidden;max-width:900px;margin:30px auto;padding:24px;gap:24px;background:#fafafa}\n.pans-globe-plug-article .product-left{flex:0 0 46%;min-width:0}.pans-globe-plug-article .product-right{flex:1;min-width:0;display:flex;flex-direction:column;justify-content:center}\n.pans-globe-plug-article .product-image{display:block;width:100%;height:auto;max-height:350px;object-fit:contain;border-radius:8px}\n.pans-globe-plug-article .product-title{font-size:24px;font-weight:600;color:#333;margin:0 0 20px;line-height:1.45}\n.pans-globe-plug-article a.product-button{background:#fff;color:#d70c19;border:2px solid #d70c19;padding:12px 24px;font-size:16px;border-radius:6px;cursor:pointer;text-decoration:none;display:inline-block;align-self:flex-start}.pans-globe-plug-article a.product-button:hover{background:#d70c19;color:#fff}\n.pans-globe-plug-article .gp-faq{margin:35px 0;padding:24px;background:#fafafa;border-top:3px solid #e60012;border-radius:8px}.pans-globe-plug-article .gp-faq h2{margin-top:0}.pans-globe-plug-article .gp-faq p:last-child{margin-bottom:0}\n@media(max-width:768px){.pans-globe-plug-article .product-card{flex-direction:column;padding:20px}.pans-globe-plug-article .product-left{width:100%;flex:auto}.pans-globe-plug-article .product-right{align-items:center;text-align:center}.pans-globe-plug-article .product-image{max-height:250px}.pans-globe-plug-article .product-title{font-size:20px}.pans-globe-plug-article a.product-button{align-self:center}}\n<\/style>\n<article class=\"pans-globe-plug-article\"><h2 class=\"wp-block-heading\" id=\"Quick_answer\"><span class=\"ez-toc-section\" id=\"Quick_answer\"><\/span>Quick answer: <span class=\"ez-toc-section-end\"><\/span><\/h2><p class=\"wp-block-paragraph\">In a globe valve vs plug valve comparison, start with the operating duty. A globe valve is commonly considered for throttling as well as shut-off, while a standard quarter-turn plug valve is commonly considered for isolation. Compare the actual trim, pressure-temperature rating, flow coefficient, seat material and maintenance requirements before approving either design.<\/p><h2 class=\"wp-block-heading\" id=\"What_is_a_Globe_Valve\"><span class=\"ez-toc-section\" id=\"What_is_a_Globe_Valve\"><\/span><strong>What is a Globe Valve?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2><p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.pansvalve.com\/blog\/globe-valve\/used-for-high-pressure\/\" data-type=\"link\" data-id=\"https:\/\/www.pansvalve.com\/blog\/globe-valve\/used-for-high-pressure\/\" target=\"_blank\" rel=\"noopener noreferrer\">Globe valves<\/a> use linear movement of a disc or trim relative to a seat to regulate or stop flow. Throttling suitability depends on the trim and service conditions; a manual stop valve is not automatically equivalent to an engineered control-valve assembly.<\/p><h3 class=\"wp-block-heading\"><strong>Advantages of Globe Valves<\/strong><\/h3><ul class=\"wp-block-list\"><li><strong>Precise Flow Control<\/strong> <\/li><\/ul><p class=\"wp-block-paragraph\">A suitable globe-valve trim can provide useful throttling in industrial service. For continuous modulation, confirm the flow characteristic, control range, differential pressure and actuator arrangement. Chemical, pharmaceutical or food service also requires material, cleanliness and any hygienic-design requirements to be checked separately; a valve-family name alone does not establish suitability.<\/p><ul class=\"wp-block-list\"><li><strong>Versatility<\/strong> <\/li><\/ul><p class=\"wp-block-paragraph\">They can handle various pressures, temperatures, and fluid types, including gases and corrosive liquids. This versatility makes them suitable for<a href=\"https:\/\/www.trane.com\/residential\/en\/resources\/glossary\/what-is-hvac\/#:~:text=HVAC%20is%20an%20acronym%20that,different%20types%20of%20HVAC%20systems.\" target=\"_blank\" rel=\"noopener noreferrer\"> HVAC<\/a>, oil and gas, and food processing industries.<\/p><ul class=\"wp-block-list\"><li><strong>Durability and Reliability<\/strong> <\/li><\/ul><p class=\"wp-block-paragraph\">Globe valves are built with robust materials and feature a simple design, making them reliable for extended use in demanding conditions.<\/p><h3 class=\"wp-block-heading\"><strong>Disadvantages of Globe Valves<\/strong><\/h3><ul class=\"wp-block-list\"><li><strong>Higher Pressure Drop <\/strong><\/li><\/ul><p class=\"wp-block-paragraph\">Changes in flow direction through a globe valve can contribute to pressure loss. Compare the selected size, trim, travel and operating point using Cv\/Kv or pressure-loss data; do not assign one pressure-drop value to every globe-valve design.<\/p><ul class=\"wp-block-list\"><li><strong>Limited Flow Capacity<\/strong><\/li><\/ul><p class=\"wp-block-paragraph\">Flow capacity depends on the selected body size, trim and opening. Check the required flow and allowable pressure drop against the proposed configuration rather than excluding an entire valve family from high-capacity service.<\/p><ul class=\"wp-block-list\"><li><strong>Cost and Maintenance <\/strong><\/li><\/ul><p class=\"wp-block-paragraph\">Globe-valve purchase and maintenance costs depend on the selected materials, trim, actuation, service conditions and inspection scope. Compare quotations and maintenance requirements on the same basis.<\/p><h2 class=\"wp-block-heading\" id=\"What_is_a_Plug_Valve\"><span class=\"ez-toc-section\" id=\"What_is_a_Plug_Valve\"><\/span><strong>What is a Plug Valve?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2><p class=\"wp-block-paragraph\">A<a href=\"https:\/\/www.pansvalve.com\/blog\/plug-valve\/what-are-the-different-types-of-plug-valves\/\" target=\"_blank\" rel=\"noopener noreferrer\"> plug valve<\/a> is a type of valve that uses a rotating cylindrical or conical plug to control the flow of fluid. The plug\u2019s rotation inside the valve housing allows it to either block or permit flow, making it ideal for quick on\/off operations. They are primarily used for on\/off control, offering quick shut-off capabilities. Their simple design makes them suitable for various industrial applications, including water treatment and chemical processing.<\/p><h3 class=\"wp-block-heading\"><strong>Advantages of Plug Valves<\/strong><\/h3><ul class=\"wp-block-list\"><li><strong>Tight Shut-Off Capability<\/strong><\/li><\/ul><p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.pansvalve.com\/plug-valve-manufacturer\/\" target=\"_blank\" rel=\"noopener noreferrer\">Plug valves<\/a> provide excellent leak prevention, making them suitable for applications where tight shut-off is critical.<\/p><ul class=\"wp-block-list\"><li>Design and Maintenance Requirements<\/li><\/ul><p class=\"wp-block-paragraph\">Plug-valve maintenance depends on the selected construction, sleeve or seat, lubrication requirements, operating torque and medium. Review service access, spares and maintenance procedures before estimating downtime or repair costs.<\/p><ul class=\"wp-block-list\"><li>Pressure Rating and Media Compatibility<\/li><\/ul><p class=\"wp-block-paragraph\">For abrasive, viscous or corrosive media, assess the actual plug geometry, bore, sleeve or seat material and solids characteristics. A sleeved design may be considered where its material and temperature limits fit the medium. Do not assume that every plug valve tolerates abrasive particles or that every globe valve is preferred for viscous fluids.<\/p><h3 class=\"wp-block-heading\"><strong>Disadvantages of Plug Valves<\/strong><\/h3><ul class=\"wp-block-list\"><li><strong>Limited Throttling Ability <\/strong><\/li><\/ul><p class=\"wp-block-paragraph\">Standard isolation plug valves should not be treated as characterized control valves without supporting design data. Purpose-built control plug valves do exist, with flow characteristics specified for the trim. Confirm the offered configuration rather than extending a statement about standard on\/off construction to every plug valve.<\/p><ul class=\"wp-block-list\"><li><strong>High Operating Torque <\/strong><\/li><\/ul><p class=\"wp-block-paragraph\">Plug valves often require significant force to operate, particularly in larger sizes. For ease of use, actuators or levers may be necessary.<\/p><ul class=\"wp-block-list\"><li><strong>Wear in Abrasive Applications <\/strong><\/li><\/ul><p class=\"wp-block-paragraph\">Continuous exposure to abrasive materials can lead to wear, increasing maintenance needs.<\/p><div class=\"product-card\"><div class=\"product-left\"><img decoding=\"async\" data-src=\"https:\/\/www.pansvalve.com\/wp-content\/uploads\/2024\/06\/1-Sleeve-Plug-Valve-1-768x768.webp\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" alt=\"Plug Valve by PANS\" class=\"product-image lazyload\" loading=\"lazy\"><noscript><img decoding=\"async\" src=\"https:\/\/www.pansvalve.com\/wp-content\/uploads\/2024\/06\/1-Sleeve-Plug-Valve-1-768x768.webp\" alt=\"Plug Valve by PANS\" class=\"product-image\" loading=\"lazy\"><\/noscript><\/div><div class=\"product-right\"><p class=\"product-title\">Why do so many projects choose our Plug Valves? <br><br>From sealing performance to durability, we deliver professional-grade solutions.<\/p><a href=\"https:\/\/www.pansvalve.com\/plug-valve-manufacturer\/\" target=\"_blank\" rel=\"noopener noreferrer\" class=\"product-button\">More Details<\/a><\/div><\/div><h2 class=\"wp-block-heading\" id=\"Comparison_Globe_Valve_vs_Plug_Valve\"><span class=\"ez-toc-section\" id=\"Globe_valve_vs_plug_valve_compare_the_same_duty\"><\/span>Globe valve vs plug valve: compare the same duty<span class=\"ez-toc-section-end\"><\/span><\/h2><div class=\"flow-table-scroll\" role=\"region\" aria-label=\"Globe and plug valve duty comparison\" tabindex=\"0\"><table><thead><tr><th scope=\"col\">Decision<\/th><th scope=\"col\">Globe valve<\/th><th scope=\"col\">Standard isolation plug valve<\/th><th scope=\"col\">Evidence to request<\/th><\/tr><\/thead><tbody><tr><th scope=\"row\">Operating motion<\/th><td>Linear stem\/disc travel<\/td><td>Quarter-turn plug rotation<\/td><td>Selected construction and actuator data<\/td><\/tr><tr><th scope=\"row\">Main duty<\/th><td>Shut-off or qualified throttling<\/td><td>Usually on\/off isolation<\/td><td>Approved duty and trim specification<\/td><\/tr><tr><th scope=\"row\">Flow capacity \/ pressure drop<\/th><td>Depends on size, trim, travel and operating point<\/td><td>Depends on port geometry, bore and opening<\/td><td>Cv\/Kv or loss data at the required flow and fluid conditions<\/td><\/tr><tr><th scope=\"row\">Pressure \/ temperature<\/th><td>Use the offered material and rating<\/td><td>Use the offered material, seat\/sleeve and rating<\/td><td>Pressure-temperature chart for the quoted configuration<\/td><\/tr><tr><th scope=\"row\">Maintenance \/ cost<\/th><td>Packing, seat and actuator access affect cost<\/td><td>Sleeve\/seat, lubrication and torque affect cost<\/td><td>Comparable quote scope, spares and maintenance procedure<\/td><\/tr><\/tbody><\/table><\/div><h2 class=\"wp-block-heading\" id=\"Factors_to_Consider_When_Choosing\"><span class=\"ez-toc-section\" id=\"Which_design_fits_the_operating_conditions\"><\/span>Which design fits the operating conditions?<span class=\"ez-toc-section-end\"><\/span><\/h2><ul><li>For throttling: check differential pressure, required control range and the risk of cavitation, flashing or erosion with the proposed trim.<\/li><li>For isolation: confirm seat-leakage acceptance, operating torque and compatibility with the intended medium.<\/li><li>For solids or viscous media: review particle size\/concentration, deposits, bore geometry and the seat or sleeve wear mechanism.<\/li><li>For high pressure or temperature: compare the offered construction, material and pressure-temperature rating; do not choose by valve-family name.<\/li><li>For lifecycle cost: compare the same size, materials, inspection scope, actuation, spares and maintenance access.<\/li><\/ul><h2 class=\"wp-block-heading\" id=\"Conclusion\"><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span><strong>Conclusion<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2><p class=\"wp-block-paragraph\">Understanding your system\u2019s specific requirements is key to choosing between a globe valve and a plug valve. Consider a suitable globe-valve trim for qualified throttling duty and a standard isolation plug valve for on\/off service. Confirm the offered construction, materials, pressure-temperature rating, flow data, maintenance needs and solids compatibility before approving either design.<\/p><p class=\"wp-block-paragraph\">To choose the correct valve, evaluate factors like flow control, fluid characteristics, pressure, and maintenance<a href=\"https:\/\/www.pansvalve.com\/\" target=\"_blank\" rel=\"noopener noreferrer\">. PANS Valve Group<\/a>, a leading <a href=\"https:\/\/www.pansvalve.com\/industrial-globe-valve-manufacturer\/\" target=\"_blank\" rel=\"noopener noreferrer\">industrial valve manufacturer<\/a> in China, offers comprehensive solutions, including design, production, and sales. Need help choosing the correct valve? Contact our experts for personalized advice, and explore the <a href=\"https:\/\/www.pansvalve.com\/product\/globe-valve\/\" target=\"_blank\" rel=\"noopener noreferrer\">Valve Selection<\/a> Guide to get started today!<\/p><div class=\"wp-block-buttons\"><div class=\"wp-block-button\"><a href=\"#quoteModal\" data-toggle=\"modal\" data-target=\"#quoteModal\" class=\"wp-block-button__link has-white-color has-red-background-color has-text-color has-background has-link-color wp-element-button\">Get a Quote<\/a><\/div><\/div><section class=\"gp-faq\"><h2><span class=\"ez-toc-section\" id=\"FAQs_for_industrial_buyers\"><\/span>FAQs for industrial buyers<span class=\"ez-toc-section-end\"><\/span><\/h2><h3>Which has lower pressure drop?<\/h3><p>The answer depends on the selected size, port or trim, opening and operating conditions. Request comparable Cv\/Kv or pressure-loss data instead of applying one value to an entire valve family.<\/p><h3>Can a plug valve throttle?<\/h3><p>A purpose-built control plug valve can regulate flow. Confirm its trim and control data; do not assume the same behavior for a standard isolation plug valve.<\/p><h3>Which is better for abrasive media?<\/h3><p>Neither family is automatically suitable. Review the particles, velocity, materials and seat or sleeve wear limits for the proposed design.<\/p><\/section><\/article>\n","protected":false},"excerpt":{"rendered":"<p>Quick answer: In a globe valve vs plug valve comparison, start with the operating duty. A globe valve is commonly considered for throttling as well as shut-off, while a standard quarter-turn plug valve is commonly considered for isolation. Compare the actual trim, pressure-temperature rating, flow coefficient, seat material and maintenance requirements before approving either design. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2305,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[186],"tags":[],"class_list":["post-2304","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-globe-valve"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Globe Valve vs Plug Valve: Industrial Selection | PANS<\/title>\n<meta name=\"description\" content=\"Compare globe valve vs plug valve designs for throttling, isolation, pressure drop and maintenance. Check the RFQ data needed for industrial service.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.pansvalve.com\/ar\/blog\/globe-valve\/globe-valve-vs-plug-valve\/\" \/>\n<meta property=\"og:locale\" content=\"ar_AR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Globe Valve vs Plug Valve: Industrial Selection | PANS\" \/>\n<meta property=\"og:description\" content=\"Compare globe valve vs plug valve designs for throttling, isolation, pressure drop and maintenance. Check the RFQ data needed for industrial service.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.pansvalve.com\/ar\/blog\/globe-valve\/globe-valve-vs-plug-valve\/\" \/>\n<meta property=\"og:site_name\" content=\"Industrial Valve Manufacturer and Company from China\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-17T01:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-24T06:09:16+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.pansvalve.com\/wp-content\/uploads\/2024\/12\/unnamed2-6763c1ae5ed13.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"1024\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0643\u064f\u062a\u0628 \u0628\u0648\u0627\u0633\u0637\u0629\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0648\u0642\u062a \u0627\u0644\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0645\u064f\u0642\u062f\u0651\u0631\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 \u062f\u0642\u0627\u0626\u0642\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/pt\\\/blog\\\/globe-valve\\\/globe-valve-vs-plug-valve\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/pt\\\/blog\\\/globe-valve\\\/globe-valve-vs-plug-valve\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/fr\\\/#\\\/schema\\\/person\\\/246e471ae246e0f35793a4f0b10b61bf\"},\"headline\":\"Globe Valve vs Plug Valve: Which is Right for Your System?\",\"datePublished\":\"2026-11-17T01:00:00+00:00\",\"dateModified\":\"2026-11-24T06:09:16+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/pt\\\/blog\\\/globe-valve\\\/globe-valve-vs-plug-valve\\\/\"},\"wordCount\":1068,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/fr\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/pt\\\/blog\\\/globe-valve\\\/globe-valve-vs-plug-valve\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.pansvalve.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/unnamed2-6763c1ae5ed13.webp\",\"articleSection\":[\"Globe Valve\"],\"inLanguage\":\"ar\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.pansvalve.com\\\/pt\\\/blog\\\/globe-valve\\\/globe-valve-vs-plug-valve\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/pt\\\/blog\\\/globe-valve\\\/globe-valve-vs-plug-valve\\\/\",\"url\":\"https:\\\/\\\/www.pansvalve.com\\\/pt\\\/blog\\\/globe-valve\\\/globe-valve-vs-plug-valve\\\/\",\"name\":\"Globe Valve vs Plug Valve: Industrial Selection | PANS\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/pt\\\/blog\\\/globe-valve\\\/globe-valve-vs-plug-valve\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/pt\\\/blog\\\/globe-valve\\\/globe-valve-vs-plug-valve\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.pansvalve.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/unnamed2-6763c1ae5ed13.webp\",\"datePublished\":\"2026-11-17T01:00:00+00:00\",\"dateModified\":\"2026-11-24T06:09:16+00:00\",\"description\":\"Compare globe valve vs plug valve designs for throttling, isolation, pressure drop and maintenance. Check the RFQ data needed for industrial service.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/pt\\\/blog\\\/globe-valve\\\/globe-valve-vs-plug-valve\\\/#breadcrumb\"},\"inLanguage\":\"ar\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.pansvalve.com\\\/pt\\\/blog\\\/globe-valve\\\/globe-valve-vs-plug-valve\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/pt\\\/blog\\\/globe-valve\\\/globe-valve-vs-plug-valve\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.pansvalve.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/unnamed2-6763c1ae5ed13.webp\",\"contentUrl\":\"https:\\\/\\\/www.pansvalve.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/unnamed2-6763c1ae5ed13.webp\",\"width\":1024,\"height\":1024},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/pt\\\/blog\\\/globe-valve\\\/globe-valve-vs-plug-valve\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.pansvalve.com\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Globe Valve vs Plug Valve: Which is Right for Your System?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/www.pansvalve.com\\\/fr\\\/\",\"name\":\"Leading Plug Vavle, Ball Valve, Gate Valve Manufacturer of China\",\"description\":\"Involving six ranges and thousands of varieties, for control valve, cyogenic valve, gate valve, globe valve, ball valve, butterfly valve, power station valve, oxygen valve, hydraulic control valve, thread valve and Antibiotic valve.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/fr\\\/#organization\"},\"alternateName\":\"PANS Valve\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.pansvalve.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ar\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/fr\\\/#organization\",\"name\":\"PANS Valve\",\"alternateName\":\"PANS\",\"url\":\"https:\\\/\\\/www.pansvalve.com\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.pansvalve.com\\\/wp-content\\\/uploads\\\/2022\\\/04\\\/\u6d59\u4e1c2.png\",\"contentUrl\":\"https:\\\/\\\/www.pansvalve.com\\\/wp-content\\\/uploads\\\/2022\\\/04\\\/\u6d59\u4e1c2.png\",\"width\":148,\"height\":52,\"caption\":\"PANS Valve\"},\"image\":{\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.pansvalve.com\\\/fr\\\/#\\\/schema\\\/person\\\/246e471ae246e0f35793a4f0b10b61bf\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a5897a878f3bac4cb5dceceea12ed045a5e21138d217ad59263f373f4e992038?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a5897a878f3bac4cb5dceceea12ed045a5e21138d217ad59263f373f4e992038?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a5897a878f3bac4cb5dceceea12ed045a5e21138d217ad59263f373f4e992038?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"https:\\\/\\\/www.pansvalve.com\"],\"url\":\"https:\\\/\\\/www.pansvalve.com\\\/ar\\\/author\\\/admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Globe Valve vs Plug Valve: Industrial Selection | PANS","description":"Compare globe valve vs plug valve designs for throttling, isolation, pressure drop and maintenance. Check the RFQ data needed for industrial service.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.pansvalve.com\/ar\/blog\/globe-valve\/globe-valve-vs-plug-valve\/","og_locale":"ar_AR","og_type":"article","og_title":"Globe Valve vs Plug Valve: Industrial Selection | PANS","og_description":"Compare globe valve vs plug valve designs for throttling, isolation, pressure drop and maintenance. Check the RFQ data needed for industrial service.","og_url":"https:\/\/www.pansvalve.com\/ar\/blog\/globe-valve\/globe-valve-vs-plug-valve\/","og_site_name":"Industrial Valve Manufacturer and Company from China","article_published_time":"2026-11-17T01:00:00+00:00","article_modified_time":"2026-11-24T06:09:16+00:00","og_image":[{"width":1024,"height":1024,"url":"https:\/\/www.pansvalve.com\/wp-content\/uploads\/2024\/12\/unnamed2-6763c1ae5ed13.webp","type":"image\/webp"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"\u0643\u064f\u062a\u0628 \u0628\u0648\u0627\u0633\u0637\u0629":"admin","\u0648\u0642\u062a \u0627\u0644\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0645\u064f\u0642\u062f\u0651\u0631":"5 \u062f\u0642\u0627\u0626\u0642"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.pansvalve.com\/pt\/blog\/globe-valve\/globe-valve-vs-plug-valve\/#article","isPartOf":{"@id":"https:\/\/www.pansvalve.com\/pt\/blog\/globe-valve\/globe-valve-vs-plug-valve\/"},"author":{"name":"admin","@id":"https:\/\/www.pansvalve.com\/fr\/#\/schema\/person\/246e471ae246e0f35793a4f0b10b61bf"},"headline":"Globe Valve vs Plug Valve: Which is Right for Your System?","datePublished":"2026-11-17T01:00:00+00:00","dateModified":"2026-11-24T06:09:16+00:00","mainEntityOfPage":{"@id":"https:\/\/www.pansvalve.com\/pt\/blog\/globe-valve\/globe-valve-vs-plug-valve\/"},"wordCount":1068,"commentCount":0,"publisher":{"@id":"https:\/\/www.pansvalve.com\/fr\/#organization"},"image":{"@id":"https:\/\/www.pansvalve.com\/pt\/blog\/globe-valve\/globe-valve-vs-plug-valve\/#primaryimage"},"thumbnailUrl":"https:\/\/www.pansvalve.com\/wp-content\/uploads\/2024\/12\/unnamed2-6763c1ae5ed13.webp","articleSection":["Globe Valve"],"inLanguage":"ar","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.pansvalve.com\/pt\/blog\/globe-valve\/globe-valve-vs-plug-valve\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.pansvalve.com\/pt\/blog\/globe-valve\/globe-valve-vs-plug-valve\/","url":"https:\/\/www.pansvalve.com\/pt\/blog\/globe-valve\/globe-valve-vs-plug-valve\/","name":"Globe Valve vs Plug Valve: Industrial Selection | PANS","isPartOf":{"@id":"https:\/\/www.pansvalve.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.pansvalve.com\/pt\/blog\/globe-valve\/globe-valve-vs-plug-valve\/#primaryimage"},"image":{"@id":"https:\/\/www.pansvalve.com\/pt\/blog\/globe-valve\/globe-valve-vs-plug-valve\/#primaryimage"},"thumbnailUrl":"https:\/\/www.pansvalve.com\/wp-content\/uploads\/2024\/12\/unnamed2-6763c1ae5ed13.webp","datePublished":"2026-11-17T01:00:00+00:00","dateModified":"2026-11-24T06:09:16+00:00","description":"Compare globe valve vs plug valve designs for throttling, isolation, pressure drop and maintenance. Check the RFQ data needed for industrial service.","breadcrumb":{"@id":"https:\/\/www.pansvalve.com\/pt\/blog\/globe-valve\/globe-valve-vs-plug-valve\/#breadcrumb"},"inLanguage":"ar","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.pansvalve.com\/pt\/blog\/globe-valve\/globe-valve-vs-plug-valve\/"]}]},{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/www.pansvalve.com\/pt\/blog\/globe-valve\/globe-valve-vs-plug-valve\/#primaryimage","url":"https:\/\/www.pansvalve.com\/wp-content\/uploads\/2024\/12\/unnamed2-6763c1ae5ed13.webp","contentUrl":"https:\/\/www.pansvalve.com\/wp-content\/uploads\/2024\/12\/unnamed2-6763c1ae5ed13.webp","width":1024,"height":1024},{"@type":"BreadcrumbList","@id":"https:\/\/www.pansvalve.com\/pt\/blog\/globe-valve\/globe-valve-vs-plug-valve\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.pansvalve.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Globe Valve vs Plug Valve: Which is Right for Your System?"}]},{"@type":"WebSite","@id":"https:\/\/www.pansvalve.com\/fr\/#website","url":"https:\/\/www.pansvalve.com\/fr\/","name":"\u0635\u0645\u0627\u0645 \u0627\u0644\u0642\u0627\u0628\u0633 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u060c \u0635\u0645\u0627\u0645 \u0627\u0644\u0643\u0631\u0629\u060c \u0635\u0645\u0627\u0645 \u0627\u0644\u0628\u0648\u0627\u0628\u0629\u060c \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0641\u064a \u0627\u0644\u0635\u064a\u0646","description":"\u062a\u062a\u0636\u0645\u0646 \u0633\u062a\u0629 \u0646\u0637\u0627\u0642\u0627\u062a \u0648\u0622\u0644\u0627\u0641 \u0627\u0644\u0623\u0635\u0646\u0627\u0641\u060c \u0644\u0635\u0645\u0627\u0645 \u0627\u0644\u062a\u062d\u0643\u0645\u060c \u0648\u0627\u0644\u0635\u0645\u0627\u0645 \u0627\u0644\u062c\u0632\u064a\u0626\u064a\u060c \u0648\u0635\u0645\u0627\u0645 \u0627\u0644\u0628\u0648\u0627\u0628\u0629\u060c \u0648\u0627\u0644\u0635\u0645\u0627\u0645 \u0627\u0644\u0643\u0631\u0648\u064a\u060c \u0648\u0627\u0644\u0635\u0645\u0627\u0645 \u0627\u0644\u0643\u0631\u0648\u064a\u060c \u0648\u0635\u0645\u0627\u0645 \u0627\u0644\u0641\u0631\u0627\u0634\u0629\u060c \u0648\u0635\u0645\u0627\u0645 \u0645\u062d\u0637\u0629 \u0627\u0644\u0637\u0627\u0642\u0629\u060c \u0648\u0635\u0645\u0627\u0645 \u0627\u0644\u0623\u0643\u0633\u062c\u064a\u0646\u060c \u0648\u0635\u0645\u0627\u0645 \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0647\u064a\u062f\u0631\u0648\u0644\u064a\u0643\u064a\u060c \u0648\u0627\u0644\u0635\u0645\u0627\u0645 \u0627\u0644\u0644\u0648\u0644\u0628\u064a\u060c \u0648\u0635\u0645\u0627\u0645 \u0627\u0644\u0645\u0636\u0627\u062f \u0627\u0644\u062d\u064a\u0648\u064a.","publisher":{"@id":"https:\/\/www.pansvalve.com\/fr\/#organization"},"alternateName":"PANS Valve","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.pansvalve.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ar"},{"@type":"Organization","@id":"https:\/\/www.pansvalve.com\/fr\/#organization","name":"\u0635\u0645\u0627\u0645 \u0627\u0644\u0645\u0642\u0627\u0644\u064a","alternateName":"PANS","url":"https:\/\/www.pansvalve.com\/fr\/","logo":{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/www.pansvalve.com\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/www.pansvalve.com\/wp-content\/uploads\/2022\/04\/\u6d59\u4e1c2.png","contentUrl":"https:\/\/www.pansvalve.com\/wp-content\/uploads\/2022\/04\/\u6d59\u4e1c2.png","width":148,"height":52,"caption":"PANS Valve"},"image":{"@id":"https:\/\/www.pansvalve.com\/fr\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.pansvalve.com\/fr\/#\/schema\/person\/246e471ae246e0f35793a4f0b10b61bf","name":"\u0645\u0633\u0624\u0644","image":{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/secure.gravatar.com\/avatar\/a5897a878f3bac4cb5dceceea12ed045a5e21138d217ad59263f373f4e992038?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/a5897a878f3bac4cb5dceceea12ed045a5e21138d217ad59263f373f4e992038?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/a5897a878f3bac4cb5dceceea12ed045a5e21138d217ad59263f373f4e992038?s=96&d=mm&r=g","caption":"admin"},"sameAs":["https:\/\/www.pansvalve.com"],"url":"https:\/\/www.pansvalve.com\/ar\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.pansvalve.com\/ar\/wp-json\/wp\/v2\/posts\/2304","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pansvalve.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pansvalve.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pansvalve.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pansvalve.com\/ar\/wp-json\/wp\/v2\/comments?post=2304"}],"version-history":[{"count":4,"href":"https:\/\/www.pansvalve.com\/ar\/wp-json\/wp\/v2\/posts\/2304\/revisions"}],"predecessor-version":[{"id":4669,"href":"https:\/\/www.pansvalve.com\/ar\/wp-json\/wp\/v2\/posts\/2304\/revisions\/4669"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.pansvalve.com\/ar\/wp-json\/wp\/v2\/media\/2305"}],"wp:attachment":[{"href":"https:\/\/www.pansvalve.com\/ar\/wp-json\/wp\/v2\/media?parent=2304"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pansvalve.com\/ar\/wp-json\/wp\/v2\/categories?post=2304"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pansvalve.com\/ar\/wp-json\/wp\/v2\/tags?post=2304"}],"curies":[{"name":"\u0648\u0648\u0631\u062f\u0628\u0631\u064a\u0633","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}